Instrument Control: Sensing and Control
trigger
kout trigger ksig, kthreshold, kmode
Description
Informs when a krate signal crosses a threshold.
Performance
ksig - input signal
kthreshold - trigger threshold
kmode - can be 0 , 1 or 2
Normally trigger outputs zeroes: only each time ksig crosses kthreshold trigger outputs a 1. There are three modes of using ktrig:
- kmode = 0 - (down-up) ktrig outputs a 1 when current value of ksig is higher than kthreshold, while old value of ksig was equal to or lower than kthreshold.
- kmode = 1 - (up-down) ktrig outputs a 1 when current value of ksig is lower than kthreshold while old value of ksig was equal or higher than kthreshold.
- kmode = 2 - (both) ktrig outputs a 1 in both the two previous cases.
Author
Gabriel Maldonado
Italy
New in Csound version 3.49
Instrument Control: Sensing and Control